Wotech Air Source Heat Pump incorporates a high-efficiency compressor, a completely new high-efficiency heat exchange system, high-precision electronic expansion valves and other accessories. COP has met national level energy efficiency standards and received national energy efficiency certification.
To reduce carbon emissions to the environment and curb global warming, Wotech developed the R290 air-to-water heat pump. With many advantages such as low carbon emissions and high efficiency, the R290 refrigerant is recognized as the refrigerant with the most potential for development in the industry, contributing to the reduction of carbon emissions and helping to achieve the global goal of carbon neutrality.
Powerful heating with high efficiency
* Little capacity attenuation at -10°C ambient temperature
* Operation temperature down to -25°C, reliable system guarantees a warm winter
* Maximum LWT upto 65°C, more efficient for radiator users.
DC inverter conversion techniques can achieve equilibrium temperatures, saving power and energy. It adopts DC frequency conversion continuously variable adjustment, which has the advantages of strong power, high efficiency, low noise, stable and reliable performance, and long service life.
• More flexibility thanks to two control zones
• Independent control of underfloor heating and radiator heating temperature
• No need to purchase an extension module for second heating system
Maintain pristine quality of the water tank's DHW and eliminate germs and bacteria by increasing the temperature of the water in it up to 65C.
Using proprietary Heating Curve Logic, users can set up the system to meet their optimum comfort levels based on the changing heat demand,insulation levels, etc Wotech air to water heat pump can adjust the outlet water temperatures based on the ambient temperature,by continually monitoring and adjusting it in opposite direction with the current ambient temperature levels to ensure the optimum comfort in the living spaces.
Wotech air to water Heat Pump for residential and commercial applications. Offering capacities from 5kW all the way up to 30kW, this ensures a system that will work regardless of your heating and cooling needs. Suitable for new build and refurbishment projects, the solutions are cost-effective with minimised environmental impact.
Wotech Air Source Heat Pump incorporates a high-efficiency compressor, a completely new high-efficiency heat exchange system, high-precision electronic expansion valves and other accessories. COP has met national level energy efficiency standards and received national energy efficiency certification.
To reduce carbon emissions to the environment and curb global warming, Wotech developed the R290 air-to-water heat pump. With many advantages such as low carbon emissions and high efficiency, the R290 refrigerant is recognized as the refrigerant with the most potential for development in the industry, contributing to the reduction of carbon emissions and helping to achieve the global goal of carbon neutrality.
Powerful heating with high efficiency
* Little capacity attenuation at -10°C ambient temperature
* Operation temperature down to -25°C, reliable system guarantees a warm winter
* Maximum LWT upto 65°C, more efficient for radiator users.
DC inverter conversion techniques can achieve equilibrium temperatures, saving power and energy. It adopts DC frequency conversion continuously variable adjustment, which has the advantages of strong power, high efficiency, low noise, stable and reliable performance, and long service life.
• More flexibility thanks to two control zones
• Independent control of underfloor heating and radiator heating temperature
• No need to purchase an extension module for second heating system
Maintain pristine quality of the water tank's DHW and eliminate germs and bacteria by increasing the temperature of the water in it up to 65C.
Using proprietary Heating Curve Logic, users can set up the system to meet their optimum comfort levels based on the changing heat demand,insulation levels, etc Wotech air to water heat pump can adjust the outlet water temperatures based on the ambient temperature,by continually monitoring and adjusting it in opposite direction with the current ambient temperature levels to ensure the optimum comfort in the living spaces.
Wotech air to water Heat Pump for residential and commercial applications. Offering capacities from 5kW all the way up to 30kW, this ensures a system that will work regardless of your heating and cooling needs. Suitable for new build and refurbishment projects, the solutions are cost-effective with minimised environmental impact.
Market model | WW05VM | WW09VM | WW15VM | WW20VT | |||||
Heating | Output Capacity | Kw | 1.89-4.80 | 3.62-9.20 | 5.89-14.96 | 8.03-20.38 | |||
Input Power | Kw | 0.36-1.09 | 0.71-2.19 | 1.21-3.72 | 1.53-4.70 | ||||
COP | - | 4.39-5.62 | 4.19-5.07 | 4.02-4.86 | 4.34-5.25 | ||||
Input Current | A | 1.64-5.01 | 3.27-10.04 | 5.55-17.04 | 2.60-7.99 | ||||
Heating | Output Capacity | Kw | 1.68-4.43 | 3.21-8.45 | 5.56-14.87 | 7.23-19.02 | |||
Input Power | Kw | 0.58-1.81 | 0.99-3.06 | 1.83-5.68 | 2.08-6.44 | ||||
COP | - | 2.45-2.89 | 2.76-3.26 | 2.62-3.09 | 2.95-3.48 | ||||
Input Current | A | 2.67-8.28 | 4.51-14.01 | 8.36-25.98 | 3.54-10.98 | ||||
Heating | Output Capacity | Kw | 2.30-5.76 | 4.49-11.22 | 7.24-18.10 | 9.78-24.46 | |||
Input Power | Kw | 0.46-1.36 | 0.94-2.75 | 1.58-4.63 | 1.98-5.80 | ||||
COP | - | 4.24-4.96 | 4.08-4.77 | 3.91-4.57 | 4.22-4.94 | ||||
Input Current | A | 2.13-6.22 | 4.30-12.59 | 7.24-21.19 | 3.37-9.86 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 1.48-3.53 | 2.95-7.03 | 3.91-9.30 | 5.63-13.41 | |||
Input Power | Kw | 0.50-1.41 | 0.98-2.76 | 1.46-4.10 | 1.89-5.32 | ||||
EER | - | 2.51-2.96 | 2.55-3.01 | 2.27-2.67 | 2.52-2.97 | ||||
Input Current | A | 2.29-6.44 | 4.49-12.62 | 6.69-18.79 | 3.22-9.05 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R290 | |||||||
Max Water Temperature(without backup heater) | ºC | 75 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | dB(A) | 49 | 50 | 53 | 58 | ||||
Net Dimension (L*W*H) | mm | 1085*440*840 | 1085*440*840 | 1150*430*960 | 1150*430*1400 |
Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.
6.Relevant EU Standards and Legislation:EN14511,EN14825
Market model | WW05VM | WW09VM | WW15VM | WW20VT | |||||
Heating | Output Capacity | Kw | 1.89-4.80 | 3.62-9.20 | 5.89-14.96 | 8.03-20.38 | |||
Input Power | Kw | 0.36-1.09 | 0.71-2.19 | 1.21-3.72 | 1.53-4.70 | ||||
COP | - | 4.39-5.62 | 4.19-5.07 | 4.02-4.86 | 4.34-5.25 | ||||
Input Current | A | 1.64-5.01 | 3.27-10.04 | 5.55-17.04 | 2.60-7.99 | ||||
Heating | Output Capacity | Kw | 1.68-4.43 | 3.21-8.45 | 5.56-14.87 | 7.23-19.02 | |||
Input Power | Kw | 0.58-1.81 | 0.99-3.06 | 1.83-5.68 | 2.08-6.44 | ||||
COP | - | 2.45-2.89 | 2.76-3.26 | 2.62-3.09 | 2.95-3.48 | ||||
Input Current | A | 2.67-8.28 | 4.51-14.01 | 8.36-25.98 | 3.54-10.98 | ||||
Heating | Output Capacity | Kw | 2.30-5.76 | 4.49-11.22 | 7.24-18.10 | 9.78-24.46 | |||
Input Power | Kw | 0.46-1.36 | 0.94-2.75 | 1.58-4.63 | 1.98-5.80 | ||||
COP | - | 4.24-4.96 | 4.08-4.77 | 3.91-4.57 | 4.22-4.94 | ||||
Input Current | A | 2.13-6.22 | 4.30-12.59 | 7.24-21.19 | 3.37-9.86 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 1.48-3.53 | 2.95-7.03 | 3.91-9.30 | 5.63-13.41 | |||
Input Power | Kw | 0.50-1.41 | 0.98-2.76 | 1.46-4.10 | 1.89-5.32 | ||||
EER | - | 2.51-2.96 | 2.55-3.01 | 2.27-2.67 | 2.52-2.97 | ||||
Input Current | A | 2.29-6.44 | 4.49-12.62 | 6.69-18.79 | 3.22-9.05 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R290 | |||||||
Max Water Temperature(without backup heater) | ºC | 75 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | dB(A) | 49 | 50 | 53 | 58 | ||||
Net Dimension (L*W*H) | mm | 1085*440*840 | 1085*440*840 | 1150*430*960 | 1150*430*1400 |
Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.
6.Relevant EU Standards and Legislation:EN14511,EN14825