Features:
Availability: | |
---|---|
With Wotech heat-cool pool heat pump,will extend your pool season by cooling your pool on hot summer days and warming your pool on cooler days when the temperature is too low for regular pool heat pumps. That's a big plus for those who want to use their pool in the spring or fall, when overnight air temperatures drop into the low 40s. Wotech swimming pool heat pump also work well for pool users in areas that want to heat their pools during the winter months.
Use low GWP R32 refrigerant,Environmental friendly
Higher efficient heating/cooling-Saving energy cost
Heating&Cooling function
Anti-UV Plastic ABS corrosion resistant casing
World brand compressor
titanium heat exchanger
LED/LCD display and control panel
The global warming coefficient of the refrigerant R32 is equal to 1/3 of the R410A,compared to the traditional R410a,the R32 is more environmentally friendly.Under the same conditions and operating frequency of the compressor,R32's cooling efficiency and energy efficiency is about 5% higher than R410a's.Therefore,R32 products are more energy efficient.
By utilizing 4 ways valve, provide both heating and cooling mode to create more possibility for pool enjoyment.
With the highlights of Anti-UV Plastic ABS corrosion resistant casing, the ABS cabinet is an ideal option for seaside citizens and area with moist, rainy climate.
Air source heat pumps are the most commonly used type of heat pump. Positioned on the exterior of your home, these heat pumps utilize an ultra-quiet fan to propel air through the evaporative section. The refrigerant liquid inside the heat pump absorbs thermal energy from the passing air, initiating the heating process. Air source heat pumps are typically self-contained, meaning that all the components are contained within the unit. The only connections to the heat pump are the flow and return pipes into the property. This convenient design makes the installation of air source heat pumps quick and easy, resulting in lower installation costs.
One limitation of air source heat pumps is their reduced efficiency in colder conditions, as the thermal energy in the air decreases. However, Wotech takes this into consideration when designing your heat pump and heating system to ensure that your home remains sufficiently heated throughout the year.
Summer vacation rentals
Homes with low heat demands
Properties with limited outdoor space
Projects with smaller budgets
To achieve optimal cost-effectiveness when installing a heat pump, whether for a renovation project or a new construction, thorough preparation is essential.
The coefficient of performance (COP) varies with outside temperatures, diminishing its efficiency during extremely cold weather. However, air source heat pumps deliver impressive performance year-round and have gained significant popularity in colder regions like Scandinavia. They are particularly compatible with underfloor heating systems due to their ability to operate at lower temperatures. While the upfront costs of installing both a heat pump and underfloor heating may seem substantial, you will notice a reduction in your electricity bill and enjoy enhanced comfort within your property within the first year. Depending on the specifics of your system and its location, it is possible to recover the costs of your heat pump within a 12-year timeframe.
If your current heating system includes radiators, you may also consider incorporating air-to-water heat pumps. If you prefer to stick with radiators and not switch to underfloor heating, it is important to ensure that the heat pump is appropriately sized to meet your heating needs. In this case, larger or double-panel radiators would be the optimal choice.
With Wotech heat-cool pool heat pump,will extend your pool season by cooling your pool on hot summer days and warming your pool on cooler days when the temperature is too low for regular pool heat pumps. That's a big plus for those who want to use their pool in the spring or fall, when overnight air temperatures drop into the low 40s. Wotech swimming pool heat pump also work well for pool users in areas that want to heat their pools during the winter months.
Use low GWP R32 refrigerant,Environmental friendly
Higher efficient heating/cooling-Saving energy cost
Heating&Cooling function
Anti-UV Plastic ABS corrosion resistant casing
World brand compressor
titanium heat exchanger
LED/LCD display and control panel
The global warming coefficient of the refrigerant R32 is equal to 1/3 of the R410A,compared to the traditional R410a,the R32 is more environmentally friendly.Under the same conditions and operating frequency of the compressor,R32's cooling efficiency and energy efficiency is about 5% higher than R410a's.Therefore,R32 products are more energy efficient.
By utilizing 4 ways valve, provide both heating and cooling mode to create more possibility for pool enjoyment.
With the highlights of Anti-UV Plastic ABS corrosion resistant casing, the ABS cabinet is an ideal option for seaside citizens and area with moist, rainy climate.
Air source heat pumps are the most commonly used type of heat pump. Positioned on the exterior of your home, these heat pumps utilize an ultra-quiet fan to propel air through the evaporative section. The refrigerant liquid inside the heat pump absorbs thermal energy from the passing air, initiating the heating process. Air source heat pumps are typically self-contained, meaning that all the components are contained within the unit. The only connections to the heat pump are the flow and return pipes into the property. This convenient design makes the installation of air source heat pumps quick and easy, resulting in lower installation costs.
One limitation of air source heat pumps is their reduced efficiency in colder conditions, as the thermal energy in the air decreases. However, Wotech takes this into consideration when designing your heat pump and heating system to ensure that your home remains sufficiently heated throughout the year.
Summer vacation rentals
Homes with low heat demands
Properties with limited outdoor space
Projects with smaller budgets
To achieve optimal cost-effectiveness when installing a heat pump, whether for a renovation project or a new construction, thorough preparation is essential.
The coefficient of performance (COP) varies with outside temperatures, diminishing its efficiency during extremely cold weather. However, air source heat pumps deliver impressive performance year-round and have gained significant popularity in colder regions like Scandinavia. They are particularly compatible with underfloor heating systems due to their ability to operate at lower temperatures. While the upfront costs of installing both a heat pump and underfloor heating may seem substantial, you will notice a reduction in your electricity bill and enjoy enhanced comfort within your property within the first year. Depending on the specifics of your system and its location, it is possible to recover the costs of your heat pump within a 12-year timeframe.
If your current heating system includes radiators, you may also consider incorporating air-to-water heat pumps. If you prefer to stick with radiators and not switch to underfloor heating, it is important to ensure that the heat pump is appropriately sized to meet your heating needs. In this case, larger or double-panel radiators would be the optimal choice.
CODE | WP05 | WP06 | WP08 | WP10 | WP12 | WP14 | WP17M |
Advised pool size (m3) | 7~14 | 8~16 | 10~20 | 15~30 | 17~34 | 20~40 | 25~50 |
Heating Performance Condition: Air 24℃, Water 26℃ | |||||||
Heating Capacity (KW) | 4.5 | 5.1 | 7.0 | 9.8 | 11.2 | 13.2 | 16.8 |
COP | 5.00 | 5.15 | 5.07 | 5.08 | 5.30 | 5.35 | 5.40 |
Heating Performance Condition: Air 15℃, Water 26℃ | |||||||
Heating Capacity (KW) | 3.7 | 3.9 | 5.2 | 7.6 | 8.7 | 10.2 | 13.5 |
COP | 4.20 | 4.32 | 4.00 | 4.11 | 4.55 | 4.60 | 4.50 |
Operating Air Temperature ℃ | -5~43 | ||||||
Power Supply (V/Hz) | 220-240V/1PH/50HZ | ||||||
Rated Input Power(KW) | 0.86 | 0.99 | 1.34 | 1.95 | 2.11 | 2.47 | 3.11 |
Rated Input Current(A) | 4.1 | 4.3 | 6.4 | 9.3 | 10.1 | 11.4 | 14.8 |
Max Heating Current (A) | 5.8 | 5.9 | 8.9 | 12.7 | 13.1 | 14.8 | 19.2 |
Water Flow Rate (m3/h) | 1.9 | 2.4 | 3.4 | 4.1 | 5.4 | 6.0 | 7.3 |
Water Connection ( inch) | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 |
Sound level at 1m (dB(A)) | 49 | 53 | 59 | 58 | 52 | 53 | 57 |
Net Dimension L*W*H(mm) | 755*258*500 | 937*286*550 | 937*286*550 | 1012*307*614 | 1012*307*614 | 1012*307*614 | 1117*396*703 |
Qty per 20ft/40HQ(PCS) | 176/445 | 128/264 | 128/264 | 90/248 | 90/248 | 90/248 | 42/132 |
The data above subject to change without prior notice.
CODE | WP17 | WP21 | WP26 | WP31 |
Advised pool size (m3) | 25~55 | 30~60 | 35~70 | 45~90 |
Heating Performance Condition: Air 24℃, Water 26℃ | ||||
Heating Capacity (KW) | 17.4 | 20.2 | 24.3 | 30.0 |
COP | 5.84 | 5.98 | 5.69 | 5.71 |
Heating Performance Condition: Air 15℃, Water 26℃ | ||||
Heating Capacity (KW) | 13.9 | 17.5 | 19.8 | 23.5 |
COP | 4.79 | 4.75 | 4.66 | 4.77 |
Operating Air Temperature ℃ | -5~43 | |||
Power Supply (V/Hz) | 380V/3PH/50HZ | |||
Rated Input Power(KW) | 2.9 | 3.26 | 4.01 | 5.25 |
Rated Input Current(A) | 5.2 | 5.8 | 7.2 | 8.8 |
Max Heating Current (A) | 6.8 | 7.7 | 9.8 | 12.0 |
Water Flow Rate (m3/h) | 7.3 | 9.0 | 11.2 | 13.3 |
Water Connection ( inch) | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 |
Sound level at 1m (dB(A)) | 57 | 57 | 60 | 60 |
Net Dimension L*W*H(mm) | 1117*396*703 | 1117*396*1053 | 1117*396*1053 | 1117*396*1053 |
Qty per 20ft/40HQ(PCS) | 42/132 | 42/88 | 42/88 | 42/88 |
CODE | WP05 | WP06 | WP08 | WP10 | WP12 | WP14 | WP17M |
Advised pool size (m3) | 7~14 | 8~16 | 10~20 | 15~30 | 17~34 | 20~40 | 25~50 |
Heating Performance Condition: Air 24℃, Water 26℃ | |||||||
Heating Capacity (KW) | 4.5 | 5.1 | 7.0 | 9.8 | 11.2 | 13.2 | 16.8 |
COP | 5.00 | 5.15 | 5.07 | 5.08 | 5.30 | 5.35 | 5.40 |
Heating Performance Condition: Air 15℃, Water 26℃ | |||||||
Heating Capacity (KW) | 3.7 | 3.9 | 5.2 | 7.6 | 8.7 | 10.2 | 13.5 |
COP | 4.20 | 4.32 | 4.00 | 4.11 | 4.55 | 4.60 | 4.50 |
Operating Air Temperature ℃ | -5~43 | ||||||
Power Supply (V/Hz) | 220-240V/1PH/50HZ | ||||||
Rated Input Power(KW) | 0.86 | 0.99 | 1.34 | 1.95 | 2.11 | 2.47 | 3.11 |
Rated Input Current(A) | 4.1 | 4.3 | 6.4 | 9.3 | 10.1 | 11.4 | 14.8 |
Max Heating Current (A) | 5.8 | 5.9 | 8.9 | 12.7 | 13.1 | 14.8 | 19.2 |
Water Flow Rate (m3/h) | 1.9 | 2.4 | 3.4 | 4.1 | 5.4 | 6.0 | 7.3 |
Water Connection ( inch) | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 |
Sound level at 1m (dB(A)) | 49 | 53 | 59 | 58 | 52 | 53 | 57 |
Net Dimension L*W*H(mm) | 755*258*500 | 937*286*550 | 937*286*550 | 1012*307*614 | 1012*307*614 | 1012*307*614 | 1117*396*703 |
Qty per 20ft/40HQ(PCS) | 176/445 | 128/264 | 128/264 | 90/248 | 90/248 | 90/248 | 42/132 |
The data above subject to change without prior notice.
CODE | WP17 | WP21 | WP26 | WP31 |
Advised pool size (m3) | 25~55 | 30~60 | 35~70 | 45~90 |
Heating Performance Condition: Air 24℃, Water 26℃ | ||||
Heating Capacity (KW) | 17.4 | 20.2 | 24.3 | 30.0 |
COP | 5.84 | 5.98 | 5.69 | 5.71 |
Heating Performance Condition: Air 15℃, Water 26℃ | ||||
Heating Capacity (KW) | 13.9 | 17.5 | 19.8 | 23.5 |
COP | 4.79 | 4.75 | 4.66 | 4.77 |
Operating Air Temperature ℃ | -5~43 | |||
Power Supply (V/Hz) | 380V/3PH/50HZ | |||
Rated Input Power(KW) | 2.9 | 3.26 | 4.01 | 5.25 |
Rated Input Current(A) | 5.2 | 5.8 | 7.2 | 8.8 |
Max Heating Current (A) | 6.8 | 7.7 | 9.8 | 12.0 |
Water Flow Rate (m3/h) | 7.3 | 9.0 | 11.2 | 13.3 |
Water Connection ( inch) | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 |
Sound level at 1m (dB(A)) | 57 | 57 | 60 | 60 |
Net Dimension L*W*H(mm) | 1117*396*703 | 1117*396*1053 | 1117*396*1053 | 1117*396*1053 |
Qty per 20ft/40HQ(PCS) | 42/132 | 42/88 | 42/88 | 42/88 |