Availability: | |
---|---|
The split system design of the heat pump, consisting of an indoor and outdoor unit, requires specialized installation by an installer qualified to work with refrigerant gases. The advantage of this solution is that there is no risk of freezing of the heating medium in case of power failure. Unlike monoblock pumps, the unit outside the building uses a non-freezing refrigerant.
R32 Gas-Low GWP
Split heat pump for home heating
House heating,cooling and domestic hot water
Inverter heat pump for home heating/cooling and DHW
Good SCOP,energy label rating W35℃ A+++/ W55℃ A++
Contributing to a descarbonised society, Floor preheating and drying.
Air source heat pumps using R32 refrigerants can not only improve the efficiency and energy utilization of equipment, but also help reduce damage to the atmosphere, making them more environmentally friendly.
Wotech heat pumps are equipped with energy-efficient inverter compressors that allow variable heating capacity adjustment. This increases the efficiency of the entire system and reduces the operating costs of the pump. The higher the coefficient, the more heat can be generated using the same amount of electricity.
we choose MITSUBISHI compressor for the heat pump. It ensures stable working in the perfect performance.
Its sustainability makes the heat pump a "green" choice. It takes heat from the environment.
*It maintains a comfortable indoor temperature while significantly reducing environmental burden.
*Wote R32 air to water Heat Pumps can also be connected to an e-heater, gas boiler, solar thermal or Py system in order to increase efficiency and minimise environmental impact.
Using proprietary Heating Curve Logic, users can set up the system to meet their optimum comfort levels based on the changing heat demand, insulation levels, etc. A constant monitoring of the current ambient temperature can enable Wotech air source heat pump to adjust the outlet water temperature in the opposite direction to ensure the optimum level of comfort in the living spaces.
Easily control your climate remotely from virtually anywhere using your smartphone or tablet. Download the application for free via the App Store and achieve optimal temperature conditions with great energy savings.
The split system design of the heat pump, consisting of an indoor and outdoor unit, requires specialized installation by an installer qualified to work with refrigerant gases. The advantage of this solution is that there is no risk of freezing of the heating medium in case of power failure. Unlike monoblock pumps, the unit outside the building uses a non-freezing refrigerant.
R32 Gas-Low GWP
Split heat pump for home heating
House heating,cooling and domestic hot water
Inverter heat pump for home heating/cooling and DHW
Good SCOP,energy label rating W35℃ A+++/ W55℃ A++
Contributing to a descarbonised society, Floor preheating and drying.
Air source heat pumps using R32 refrigerants can not only improve the efficiency and energy utilization of equipment, but also help reduce damage to the atmosphere, making them more environmentally friendly.
Wotech heat pumps are equipped with energy-efficient inverter compressors that allow variable heating capacity adjustment. This increases the efficiency of the entire system and reduces the operating costs of the pump. The higher the coefficient, the more heat can be generated using the same amount of electricity.
we choose MITSUBISHI compressor for the heat pump. It ensures stable working in the perfect performance.
Its sustainability makes the heat pump a "green" choice. It takes heat from the environment.
*It maintains a comfortable indoor temperature while significantly reducing environmental burden.
*Wote R32 air to water Heat Pumps can also be connected to an e-heater, gas boiler, solar thermal or Py system in order to increase efficiency and minimise environmental impact.
Using proprietary Heating Curve Logic, users can set up the system to meet their optimum comfort levels based on the changing heat demand, insulation levels, etc. A constant monitoring of the current ambient temperature can enable Wotech air source heat pump to adjust the outlet water temperature in the opposite direction to ensure the optimum level of comfort in the living spaces.
Easily control your climate remotely from virtually anywhere using your smartphone or tablet. Download the application for free via the App Store and achieve optimal temperature conditions with great energy savings.
Market model | WW08VM-O | WW12VM-O | WW16VM-O | WW20VT-O | |||||
Heating | Output Capacity | Kw | 3.23-8.20 | 4.78-12.13 | 6.58-16.71 | 8.14-20.67 | |||
Input Power | Kw | 0.58-1.75 | 0.89-2.75 | 1.21-3.72 | 1.45-4.24 | ||||
COP | - | 4.68-5.62 | 4.42-5.35 | 4.49-5.43 | 4.87-5.60 | ||||
Input Current | A | 2.63-8.01 | 4.09-12.59 | 5.54-17.03 | 2.47-7.21 | ||||
Heating | Output Capacity | Kw | 2.73-7.19 | 4.16-10.94 | 5.54-14.57 | 7.41-19.50 | |||
Input Power | Kw | 0.96-2.51 | 1.35-4.19 | 1.68-5.20 | 1.95-6.06 | ||||
COP | - | 2.86-3.37 | 2.61-3.08 | 2.80-3.30 | 3.22-3.80 | ||||
Input Current | A | 4.37-11.50 | 6.18-19.18 | 7.67-23.81 | 3.32-10.30 | ||||
Heating | Output Capacity | Kw | 3.88-9.84 | 5.73-14.56 | 7.90-20.05 | 9.77-24.80 | |||
Input Power | Kw | 0.80-2.23 | 1.23-3.42 | 1.69-4.71 | 2.04-5.70 | ||||
COP | - | 4.42-4.86 | 4.25-4.68 | 4.26-4.69 | 4.35-4.79 | ||||
Input Current | A | 3.65-10.19 | 5.61-15.67 | 7.71-21.54 | 3.47-9.70 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 2.74-6.53 | 4.07-9.70 | 5.28-12.58 | 6.57-15.65 | |||
Input Power | Kw | 0.88-2.48 | 1.30-3.66 | 1.59-4.48 | 1.99-5.20 | ||||
EER | - | 2.63-3.10 | 2.65-3.13 | 2.81-3.32 | 3.01-3.31 | ||||
Input Current | A | 4.04-11.35 | 5.96-16.75 | 7.29-20.49 | 3.38-8.84 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R32 | |||||||
Max Water Temperature(without backup heater) | ºC | 60 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | outdoor unit | dB(A) | 50 | 52 | 56 | 58 | |||
indoor unit | 27 | 27 | 27 | 27 | |||||
Net Dimension (L*W*H) | outdoor unit | mm | 1070*410*840 | 1070*410*960 | 1070*410*960 | 1150*430*1400 | |||
indoor unit | 475*220*800 | 475*220*800 | 475*220*800 | 475*220*800 |
Market model | WW08VM-O | WW12VM-O | WW16VM-O | WW20VT-O | |||||
Heating | Output Capacity | Kw | 3.23-8.20 | 4.78-12.13 | 6.58-16.71 | 8.14-20.67 | |||
Input Power | Kw | 0.58-1.75 | 0.89-2.75 | 1.21-3.72 | 1.45-4.24 | ||||
COP | - | 4.68-5.62 | 4.42-5.35 | 4.49-5.43 | 4.87-5.60 | ||||
Input Current | A | 2.63-8.01 | 4.09-12.59 | 5.54-17.03 | 2.47-7.21 | ||||
Heating | Output Capacity | Kw | 2.73-7.19 | 4.16-10.94 | 5.54-14.57 | 7.41-19.50 | |||
Input Power | Kw | 0.96-2.51 | 1.35-4.19 | 1.68-5.20 | 1.95-6.06 | ||||
COP | - | 2.86-3.37 | 2.61-3.08 | 2.80-3.30 | 3.22-3.80 | ||||
Input Current | A | 4.37-11.50 | 6.18-19.18 | 7.67-23.81 | 3.32-10.30 | ||||
Heating | Output Capacity | Kw | 3.88-9.84 | 5.73-14.56 | 7.90-20.05 | 9.77-24.80 | |||
Input Power | Kw | 0.80-2.23 | 1.23-3.42 | 1.69-4.71 | 2.04-5.70 | ||||
COP | - | 4.42-4.86 | 4.25-4.68 | 4.26-4.69 | 4.35-4.79 | ||||
Input Current | A | 3.65-10.19 | 5.61-15.67 | 7.71-21.54 | 3.47-9.70 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 2.74-6.53 | 4.07-9.70 | 5.28-12.58 | 6.57-15.65 | |||
Input Power | Kw | 0.88-2.48 | 1.30-3.66 | 1.59-4.48 | 1.99-5.20 | ||||
EER | - | 2.63-3.10 | 2.65-3.13 | 2.81-3.32 | 3.01-3.31 | ||||
Input Current | A | 4.04-11.35 | 5.96-16.75 | 7.29-20.49 | 3.38-8.84 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R32 | |||||||
Max Water Temperature(without backup heater) | ºC | 60 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | outdoor unit | dB(A) | 50 | 52 | 56 | 58 | |||
indoor unit | 27 | 27 | 27 | 27 | |||||
Net Dimension (L*W*H) | outdoor unit | mm | 1070*410*840 | 1070*410*960 | 1070*410*960 | 1150*430*1400 | |||