In the monoblock type heat pump, the refrigerant system is completely integrated in the external unit. Such a solution ensures, above all, good thermal insulation, space saving and quiet operation of the device. In addition, the compact design ensures easy installation and simple maintenance.
Wotech R32 Air to Water Heat Pump is specially developed with the most cutting-edge heat pump technology and modern design to meet stringent requirements for efficiency, stability and quietness. Not only does it use R32 green gas and inverter technology, but it is also rated with the A++ energy label. With a top energy rating of A+++, the unit is energy efficient and can significantly reduce the user's energy bill.
Wotech's new line of heat pumps now utilizes the R32 multifunction series gas solution, providing a number of benefits including:
1. Enhanced environmental performance due to the R32 heat pump's GWP being only one-third that of R410A refrigerant.
2. High energy efficiency, reaching A+++ energy level according to EU regulation. By utilizing heat from the outside air, the system minimizes energy consumption while maintaining a comfortable environment. The system requires minimal maintenance, ensuring low running costs. Additionally, with inverter technology, energy savings are further maximized.
Wotech heat pumps are equipped with energy-efficient inverter compressors that allow variable heating capacity adjustment. This increases the efficiency of the entire system and reduces the operating costs of the pump. The higher the coefficient, the more heat can be generated using the same amount of electricity.
We choose MITSUBISHI compressor for the heat pump. It ensures stable working in the perfect performance.
• More flexibility thanks to two control zones
• Independent control of underfloor heating and radiator heating temperature
• No need to purchase an extension module for second heating system
Smart design to work with other heating facilities in your house, like solar, gas boiler and etc, make sure you to pay the lowest bill for heating !
By heating the water in the system to 65°C, the high temperature kills most bacteria (including Legionella).
The air source heat pump is equipped with the Eco mode function, which can achieve more effective energy utilization and better environmental protection.
With Floor Preheating, you can avoid potential floor damage and smoothly transition from the preheating to the heating function, avoiding any floor damage.In addition to protecting the installation, the Floor Drying Up function ensures the heat pump operates optimally and effectively by removing any residual moisture from newly installed floor coils.
In the monoblock type heat pump, the refrigerant system is completely integrated in the external unit. Such a solution ensures, above all, good thermal insulation, space saving and quiet operation of the device. In addition, the compact design ensures easy installation and simple maintenance.
Wotech R32 Air to Water Heat Pump is specially developed with the most cutting-edge heat pump technology and modern design to meet stringent requirements for efficiency, stability and quietness. Not only does it use R32 green gas and inverter technology, but it is also rated with the A++ energy label. With a top energy rating of A+++, the unit is energy efficient and can significantly reduce the user's energy bill.
Wotech's new line of heat pumps now utilizes the R32 multifunction series gas solution, providing a number of benefits including:
1. Enhanced environmental performance due to the R32 heat pump's GWP being only one-third that of R410A refrigerant.
2. High energy efficiency, reaching A+++ energy level according to EU regulation. By utilizing heat from the outside air, the system minimizes energy consumption while maintaining a comfortable environment. The system requires minimal maintenance, ensuring low running costs. Additionally, with inverter technology, energy savings are further maximized.
Wotech heat pumps are equipped with energy-efficient inverter compressors that allow variable heating capacity adjustment. This increases the efficiency of the entire system and reduces the operating costs of the pump. The higher the coefficient, the more heat can be generated using the same amount of electricity.
We choose MITSUBISHI compressor for the heat pump. It ensures stable working in the perfect performance.
• More flexibility thanks to two control zones
• Independent control of underfloor heating and radiator heating temperature
• No need to purchase an extension module for second heating system
Smart design to work with other heating facilities in your house, like solar, gas boiler and etc, make sure you to pay the lowest bill for heating !
By heating the water in the system to 65°C, the high temperature kills most bacteria (including Legionella).
The air source heat pump is equipped with the Eco mode function, which can achieve more effective energy utilization and better environmental protection.
With Floor Preheating, you can avoid potential floor damage and smoothly transition from the preheating to the heating function, avoiding any floor damage.In addition to protecting the installation, the Floor Drying Up function ensures the heat pump operates optimally and effectively by removing any residual moisture from newly installed floor coils.
Market model | WW08VM | WW12VM | WW16VM | WW20VT | |||||
Heating | Output Capacity | Kw | 4.78-12.13 | 4.78-12.13 | 6.58-16.71 | 8.14-20.67 | |||
Input Power | Kw | 0.58-1.75 | 0.89-2.75 | 1.21-3.72 | 1.45-4.24 | ||||
COP | - | 4.68-5.62 | 4.42-5.35 | 4.49-5.43 | 4.87-5.60 | ||||
Input Current | A | 2.63-8.01 | 4.09-12.59 | 5.54-17.03 | 2.47-7.21 | ||||
Heating | Output Capacity | Kw | 2.73-7.19 | 4.16-10.94 | 5.54-14.57 | 7.41-19.50 | |||
Input Power | Kw | 0.96-2.51 | 1.35-4.19 | 1.68-5.20 | 1.95-6.06 | ||||
COP | - | 2.86-3.37 | 2.61-3.08 | 2.80-3.30 | 3.22-3.80 | ||||
Input Current | A | 4.37-11.50 | 6.18-19.18 | 7.67-23.81 | 3.32-10.30 | ||||
Heating | Output Capacity | Kw | 3.88-9.84 | 5.73-14.56 | 7.90-20.05 | 9.77-24.80 | |||
Input Power | Kw | 0.80-2.23 | 1.23-3.42 | 1.69-4.71 | 2.04-5.70 | ||||
COP | - | 4.42-4.86 | 4.25-4.68 | 4.26-4.69 | 4.35-4.79 | ||||
Input Current | A | 3.65-10.19 | 5.61-15.67 | 7.71-21.54 | 3.47-9.70 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 2.74-6.53 | 4.07-9.70 | 5.28-12.58 | 6.57-15.65 | |||
Input Power | Kw | 0.88-2.48 | 1.30-3.66 | 1.59-4.48 | 1.99-5.20 | ||||
EER | - | 2.63-3.10 | 2.65-3.13 | 2.81-3.32 | 3.01-3.31 | ||||
Input Current | A | 4.04-11.35 | 5.96-16.75 | 7.29-20.49 | 3.38-8.84 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R32 | |||||||
Max Water Temperature(without backup heater) | ºC | 60 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | dB(A) | 50 | 52 | 56 | 58 | ||||
Net Dimension (L*W*H) | mm | 1085*410*840 | 1150*430*960 | 1150*430*960 | 1150*430*1400 |
Market model | WW08VM | WW12VM | WW16VM | WW20VT | |||||
Heating | Output Capacity | Kw | 4.78-12.13 | 4.78-12.13 | 6.58-16.71 | 8.14-20.67 | |||
Input Power | Kw | 0.58-1.75 | 0.89-2.75 | 1.21-3.72 | 1.45-4.24 | ||||
COP | - | 4.68-5.62 | 4.42-5.35 | 4.49-5.43 | 4.87-5.60 | ||||
Input Current | A | 2.63-8.01 | 4.09-12.59 | 5.54-17.03 | 2.47-7.21 | ||||
Heating | Output Capacity | Kw | 2.73-7.19 | 4.16-10.94 | 5.54-14.57 | 7.41-19.50 | |||
Input Power | Kw | 0.96-2.51 | 1.35-4.19 | 1.68-5.20 | 1.95-6.06 | ||||
COP | - | 2.86-3.37 | 2.61-3.08 | 2.80-3.30 | 3.22-3.80 | ||||
Input Current | A | 4.37-11.50 | 6.18-19.18 | 7.67-23.81 | 3.32-10.30 | ||||
Heating | Output Capacity | Kw | 3.88-9.84 | 5.73-14.56 | 7.90-20.05 | 9.77-24.80 | |||
Input Power | Kw | 0.80-2.23 | 1.23-3.42 | 1.69-4.71 | 2.04-5.70 | ||||
COP | - | 4.42-4.86 | 4.25-4.68 | 4.26-4.69 | 4.35-4.79 | ||||
Input Current | A | 3.65-10.19 | 5.61-15.67 | 7.71-21.54 | 3.47-9.70 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 2.74-6.53 | 4.07-9.70 | 5.28-12.58 | 6.57-15.65 | |||
Input Power | Kw | 0.88-2.48 | 1.30-3.66 | 1.59-4.48 | 1.99-5.20 | ||||
EER | - | 2.63-3.10 | 2.65-3.13 | 2.81-3.32 | 3.01-3.31 | ||||
Input Current | A | 4.04-11.35 | 5.96-16.75 | 7.29-20.49 | 3.38-8.84 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R32 | |||||||
Max Water Temperature(without backup heater) | ºC | 60 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | dB(A) | 50 | 52 | 56 | 58 | ||||
Net Dimension (L*W*H) | mm | 1085*410*840 | 1150*430*960 | 1150*430*960 | 1150*430*1400 |