R32 refrigerant is the latest industry alternative and is expected to replace R410A. It is a hydrofluorocarbon molecule that has several benefits, such as improved energy efficiency, reduced environmental impact, and enhanced safety - all important factors to consider when evaluating refrigerant suitability. As compared to R410A, R32 outperforms in each index. Additionally, because of anticipated restrictions, you may be required to buy R32 anyway.
As well as being energy efficient and cost-effective, an R32 heat pump offers many other benefits. As a result of its ability to recharge and recycle more efficiently than other refrigerants, it can function at much higher efficiency ratings than other refrigerants.
As a result, your regular energy bills will be lower and your performance won't suffer since this heat pump requires less energy to heat and cool your home. The flow required per unit flow is smaller and the COP is higher since the heat required to evaporate R32 is greater than the heat required to evaporate R410A.
Heat pumps with higher SCOP readings produce more heating capacity per unit of energy used, resulting in higher RHI payments.In the same heat pump system, R32 can be charged less than R410A because of its lower liquid density.
Thanks to its Anti-UV Plastic ABS casing that is resistant to corrosion, the ABS cabinet is a perfect solution for those living in coastal areas or regions with humid and rainy weather.
R32 refrigerant is the latest industry alternative and is expected to replace R410A. It is a hydrofluorocarbon molecule that has several benefits, such as improved energy efficiency, reduced environmental impact, and enhanced safety - all important factors to consider when evaluating refrigerant suitability. As compared to R410A, R32 outperforms in each index. Additionally, because of anticipated restrictions, you may be required to buy R32 anyway.
As well as being energy efficient and cost-effective, an R32 heat pump offers many other benefits. As a result of its ability to recharge and recycle more efficiently than other refrigerants, it can function at much higher efficiency ratings than other refrigerants.
As a result, your regular energy bills will be lower and your performance won't suffer since this heat pump requires less energy to heat and cool your home. The flow required per unit flow is smaller and the COP is higher since the heat required to evaporate R32 is greater than the heat required to evaporate R410A.
Heat pumps with higher SCOP readings produce more heating capacity per unit of energy used, resulting in higher RHI payments.In the same heat pump system, R32 can be charged less than R410A because of its lower liquid density.
Thanks to its Anti-UV Plastic ABS casing that is resistant to corrosion, the ABS cabinet is a perfect solution for those living in coastal areas or regions with humid and rainy weather.
CODE | WP05 | WP06 | WP08 | WP10 | WP12 | WP14 | WP17M |
Advised pool size (m3) | 7~14 | 8~16 | 10~20 | 14~28 | 17~34 | 20~40 | 25~50 |
Heating Performance Condition: Air 24ºC, Water 26ºC | |||||||
Heating Capacity (KW) | 4.6 | 5.3 | 7.2 | 9.7 | 11.6 | 14.3 | 17 |
COP | 5.11 | 5.25 | 5.33 | 5.19 | 5.42 | 6.03 | 5.85 |
Heating Performance Condition: Air 15ºC, Water 26ºC | |||||||
Heating Capacity (KW) | 3.8 | 4.1 | 5.9 | 8.2 | 9.1 | 11.8 | 13.7 |
COP | 4.25 | 4.43 | 4.5 | 4.71 | 4.71 | 5.18 | 5.18 |
Operating Air Temperature ºC | -5~43 | ||||||
Power Supply (V/Hz) | 220-240V/1PH/50HZ | ||||||
Rated Input Power(KW) | 0.9 | 1.01 | 1.35 | 1.87 | 2.14 | 2.37 | 2.91 |
Rated Input Current(A) | 4.3 | 4.8 | 6.5 | 8.9 | 10.2 | 11.3 | 13.9 |
Max Heating Current (A) | 5.3 | 6 | 8.5 | 11.6 | 12.6 | 14.2 | 18.1 |
Water Flow Rate (m3/h) | 1.9 | 2.4 | 3.4 | 4.1 | 5.4 | 6 | 7.3 |
Water Connection ( inch) | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 |
Sound level at 1m (dB(A)) | 55 | 53 | 52 | 52 | 56 | 55 | 55 |
Net Dimension L*W*H(mm) | 810*293*515 | 810*293*515 | 970*360*585 | 1045*370*625 | 1045*370*625 | 1110*416*711 | 1110*416*711 |
Qty per 20ft/40HQ(PCS) | 160/328 | 160/328 | 90/240 | 84/232 | 84/232 | 48/156 | 48/156 |
Remarks:The Specifications are subject to changes without notice. |
CODE | WP17 | WP21 | WP26 | WP31 |
Advised pool size (m3) | 25~55 | 30~60 | 35~70 | 45~90 |
Heating Performance Condition: Air 24ºC, Water 26ºC | ||||
Heating Capacity (KW) | 17.8 | 21.2 | 25.2 | 30.3 |
COP | 6.03 | 6.2 | 6 | 6.04 |
Heating Performance Condition: Air 15ºC, Water 26ºC | ||||
Heating Capacity (KW) | 15.2 | 18.1 | 21.3 | 24 |
COP | 5.17 | 5.4 | 5.13 | 5.05 |
Operating Air Temperature ºC | -5~43 | |||
Power Supply (V/Hz) | 380V/3PH/50HZ | |||
Rated Input Power(KW) | 2.95 | 3.42 | 4.2 | 5.02 |
Rated Input Current(A) | 5.3 | 6.1 | 7.5 | 10.2 |
Max Heating Current (A) | 6.7 | 7.3 | 9.1 | 13 |
Water Flow Rate (m3/h) | 7.3 | 9 | 11.2 | 13.3 |
Water Connection ( inch) | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 |
Sound level at 1m (dB(A)) | 59 | 60 | 60 | 60 |
Net Dimension L*W*H(mm) | 1110*416*711 | 1110*446*958 | 1110*446*1260 | 1110*446*1260 |
Qty per 20ft/40HQ(PCS) | 48/156 | 48/96 | 24/48 | 24/48 |
Remarks:The Specifications are subject to changes without notice. |
CODE | WP05 | WP06 | WP08 | WP10 | WP12 | WP14 | WP17M |
Advised pool size (m3) | 7~14 | 8~16 | 10~20 | 14~28 | 17~34 | 20~40 | 25~50 |
Heating Performance Condition: Air 24ºC, Water 26ºC | |||||||
Heating Capacity (KW) | 4.6 | 5.3 | 7.2 | 9.7 | 11.6 | 14.3 | 17 |
COP | 5.11 | 5.25 | 5.33 | 5.19 | 5.42 | 6.03 | 5.85 |
Heating Performance Condition: Air 15ºC, Water 26ºC | |||||||
Heating Capacity (KW) | 3.8 | 4.1 | 5.9 | 8.2 | 9.1 | 11.8 | 13.7 |
COP | 4.25 | 4.43 | 4.5 | 4.71 | 4.71 | 5.18 | 5.18 |
Operating Air Temperature ºC | -5~43 | ||||||
Power Supply (V/Hz) | 220-240V/1PH/50HZ | ||||||
Rated Input Power(KW) | 0.9 | 1.01 | 1.35 | 1.87 | 2.14 | 2.37 | 2.91 |
Rated Input Current(A) | 4.3 | 4.8 | 6.5 | 8.9 | 10.2 | 11.3 | 13.9 |
Max Heating Current (A) | 5.3 | 6 | 8.5 | 11.6 | 12.6 | 14.2 | 18.1 |
Water Flow Rate (m3/h) | 1.9 | 2.4 | 3.4 | 4.1 | 5.4 | 6 | 7.3 |
Water Connection ( inch) | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 |
Sound level at 1m (dB(A)) | 55 | 53 | 52 | 52 | 56 | 55 | 55 |
Net Dimension L*W*H(mm) | 810*293*515 | 810*293*515 | 970*360*585 | 1045*370*625 | 1045*370*625 | 1110*416*711 | 1110*416*711 |
Qty per 20ft/40HQ(PCS) | 160/328 | 160/328 | 90/240 | 84/232 | 84/232 | 48/156 | 48/156 |
Remarks:The Specifications are subject to changes without notice. |
CODE | WP17 | WP21 | WP26 | WP31 |
Advised pool size (m3) | 25~55 | 30~60 | 35~70 | 45~90 |
Heating Performance Condition: Air 24ºC, Water 26ºC | ||||
Heating Capacity (KW) | 17.8 | 21.2 | 25.2 | 30.3 |
COP | 6.03 | 6.2 | 6 | 6.04 |
Heating Performance Condition: Air 15ºC, Water 26ºC | ||||
Heating Capacity (KW) | 15.2 | 18.1 | 21.3 | 24 |
COP | 5.17 | 5.4 | 5.13 | 5.05 |
Operating Air Temperature ºC | -5~43 | |||
Power Supply (V/Hz) | 380V/3PH/50HZ | |||
Rated Input Power(KW) | 2.95 | 3.42 | 4.2 | 5.02 |
Rated Input Current(A) | 5.3 | 6.1 | 7.5 | 10.2 |
Max Heating Current (A) | 6.7 | 7.3 | 9.1 | 13 |
Water Flow Rate (m3/h) | 7.3 | 9 | 11.2 | 13.3 |
Water Connection ( inch) | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 |
Sound level at 1m (dB(A)) | 59 | 60 | 60 | 60 |
Net Dimension L*W*H(mm) | 1110*416*711 | 1110*446*958 | 1110*446*1260 | 1110*446*1260 |
Qty per 20ft/40HQ(PCS) | 48/156 | 48/96 | 24/48 | 24/48 |
Remarks:The Specifications are subject to changes without notice. |