Availability: | |
---|---|
1.High efficiency and eco-friendly Refrigerant
2.High COP(Coefficientofperformance),it can reduce the running cost by 70%-80% compared with other ordinary hot water equipment
3.Can heat and cool the water or keep water temperature constant for pool
4.Dual speed fan for extra energy efficiency and noise reduction
suiable for Koi ponds as well as swimming pools and sauna or SPA
5.Defrosting under low temperature to avoid freezing works down to -10C
6.Titanium heat exchnager-Use patented hig-performance titanium exchanger made from one model by Wotech sub-company.
It has more stable performance,which leads to efficient heat transfer without any dangers of corrosion from chlorine in the water,and createds a longer lifespan.
7.The elegant digital remote control and panel,panted socket-style PCB make maintains easier and operation simple
8.Use the high-efficiency,low sound rotary or scroll compressor,low noise fan.
9.The new generation water flow switch with better performance and longer lifetime.
10.We fuse intelligent,wireless,central control and monitor multiple units with full IT company internet interface that can be applied worldwide
Wide working temperature range-Extend swimming seasons
It is less combustible and less toxic, which is good for human health.
There is also a wider context.
Air source heat pumps are a higher efficient solution for both heating and cooling needs in buildings. One of the key components that make them so effective is the 4 way valve, which allows the heat pump to switch between heating and cooling modes with ease. This valve works by reversing the flow of refrigerant, which allows the heat pump to extract heat from the air outside and transfer it inside during the heating season, and extract heat from inside and transfer it outside during the cooling season. By utilizing this technology, air source heat pumps can achieve higher efficiency levels compared to traditional heating and cooling systems.
Thanks to its Anti-UV Plastic ABS casing that is resistant to corrosion, the ABS cabinet is a perfect solution for those living in coastal areas or regions with humid and rainy weather.
1.High efficiency and eco-friendly Refrigerant
2.High COP(Coefficientofperformance),it can reduce the running cost by 70%-80% compared with other ordinary hot water equipment
3.Can heat and cool the water or keep water temperature constant for pool
4.Dual speed fan for extra energy efficiency and noise reduction
suiable for Koi ponds as well as swimming pools and sauna or SPA
5.Defrosting under low temperature to avoid freezing works down to -10C
6.Titanium heat exchnager-Use patented hig-performance titanium exchanger made from one model by Wotech sub-company.
It has more stable performance,which leads to efficient heat transfer without any dangers of corrosion from chlorine in the water,and createds a longer lifespan.
7.The elegant digital remote control and panel,panted socket-style PCB make maintains easier and operation simple
8.Use the high-efficiency,low sound rotary or scroll compressor,low noise fan.
9.The new generation water flow switch with better performance and longer lifetime.
10.We fuse intelligent,wireless,central control and monitor multiple units with full IT company internet interface that can be applied worldwide
Wide working temperature range-Extend swimming seasons
It is less combustible and less toxic, which is good for human health.
There is also a wider context.
Air source heat pumps are a higher efficient solution for both heating and cooling needs in buildings. One of the key components that make them so effective is the 4 way valve, which allows the heat pump to switch between heating and cooling modes with ease. This valve works by reversing the flow of refrigerant, which allows the heat pump to extract heat from the air outside and transfer it inside during the heating season, and extract heat from inside and transfer it outside during the cooling season. By utilizing this technology, air source heat pumps can achieve higher efficiency levels compared to traditional heating and cooling systems.
Thanks to its Anti-UV Plastic ABS casing that is resistant to corrosion, the ABS cabinet is a perfect solution for those living in coastal areas or regions with humid and rainy weather.
CODE | WP05 | WP06 | WP08 | WP10 | WP12 | WP14 | WP17M |
Advised pool size (m3) | 7~14 | 8~16 | 10~20 | 14~28 | 17~34 | 20~40 | 25~50 |
Heating Performance Condition: Air 24ºC, Water 26ºC | |||||||
Heating Capacity (KW) | 4.6 | 5.3 | 7.2 | 9.7 | 11.6 | 14.3 | 17 |
COP | 5.11 | 5.25 | 5.33 | 5.19 | 5.42 | 6.03 | 5.85 |
Heating Performance Condition: Air 15ºC, Water 26ºC | |||||||
Heating Capacity (KW) | 3.8 | 4.1 | 5.9 | 8.2 | 9.1 | 11.8 | 13.7 |
COP | 4.25 | 4.43 | 4.5 | 4.71 | 4.71 | 5.18 | 5.18 |
Operating Air Temperature ºC | -5~43 | ||||||
Power Supply (V/Hz) | 220-240V/1PH/50HZ | ||||||
Rated Input Power(KW) | 0.9 | 1.01 | 1.35 | 1.87 | 2.14 | 2.37 | 2.91 |
Rated Input Current(A) | 4.3 | 4.8 | 6.5 | 8.9 | 10.2 | 11.3 | 13.9 |
Max Heating Current (A) | 5.3 | 6 | 8.5 | 11.6 | 12.6 | 14.2 | 18.1 |
Water Flow Rate (m3/h) | 1.9 | 2.4 | 3.4 | 4.1 | 5.4 | 6 | 7.3 |
Water Connection ( inch) | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 |
Sound level at 1m (dB(A)) | 55 | 53 | 52 | 52 | 56 | 55 | 55 |
Net Dimension L*W*H(mm) | 810*293*515 | 810*293*515 | 970*360*585 | 1045*370*625 | 1045*370*625 | 1110*416*711 | 1110*416*711 |
Qty per 20ft/40HQ(PCS) | 160/328 | 160/328 | 90/240 | 84/232 | 84/232 | 48/156 | 48/156 |
Remarks:The Specifications are subject to changes without notice. |
CODE | WP17 | WP21 | WP26 | WP31 |
Advised pool size (m3) | 25~55 | 30~60 | 35~70 | 45~90 |
Heating Performance Condition: Air 24ºC, Water 26ºC | ||||
Heating Capacity (KW) | 17.8 | 21.2 | 25.2 | 30.3 |
COP | 6.03 | 6.2 | 6 | 6.04 |
Heating Performance Condition: Air 15ºC, Water 26ºC | ||||
Heating Capacity (KW) | 15.2 | 18.1 | 21.3 | 24 |
COP | 5.17 | 5.4 | 5.13 | 5.05 |
Operating Air Temperature ºC | -5~43 | |||
Power Supply (V/Hz) | 380V/3PH/50HZ | |||
Rated Input Power(KW) | 2.95 | 3.42 | 4.2 | 5.02 |
Rated Input Current(A) | 5.3 | 6.1 | 7.5 | 10.2 |
Max Heating Current (A) | 6.7 | 7.3 | 9.1 | 13 |
Water Flow Rate (m3/h) | 7.3 | 9 | 11.2 | 13.3 |
Water Connection ( inch) | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 |
Sound level at 1m (dB(A)) | 59 | 60 | 60 | 60 |
Net Dimension L*W*H(mm) | 1110*416*711 | 1110*446*958 | 1110*446*1260 | 1110*446*1260 |
Qty per 20ft/40HQ(PCS) | 48/156 | 48/96 | 24/48 | 24/48 |
Remarks:The Specifications are subject to changes without notice. |
CODE | WP05 | WP06 | WP08 | WP10 | WP12 | WP14 | WP17M |
Advised pool size (m3) | 7~14 | 8~16 | 10~20 | 14~28 | 17~34 | 20~40 | 25~50 |
Heating Performance Condition: Air 24ºC, Water 26ºC | |||||||
Heating Capacity (KW) | 4.6 | 5.3 | 7.2 | 9.7 | 11.6 | 14.3 | 17 |
COP | 5.11 | 5.25 | 5.33 | 5.19 | 5.42 | 6.03 | 5.85 |
Heating Performance Condition: Air 15ºC, Water 26ºC | |||||||
Heating Capacity (KW) | 3.8 | 4.1 | 5.9 | 8.2 | 9.1 | 11.8 | 13.7 |
COP | 4.25 | 4.43 | 4.5 | 4.71 | 4.71 | 5.18 | 5.18 |
Operating Air Temperature ºC | -5~43 | ||||||
Power Supply (V/Hz) | 220-240V/1PH/50HZ | ||||||
Rated Input Power(KW) | 0.9 | 1.01 | 1.35 | 1.87 | 2.14 | 2.37 | 2.91 |
Rated Input Current(A) | 4.3 | 4.8 | 6.5 | 8.9 | 10.2 | 11.3 | 13.9 |
Max Heating Current (A) | 5.3 | 6 | 8.5 | 11.6 | 12.6 | 14.2 | 18.1 |
Water Flow Rate (m3/h) | 1.9 | 2.4 | 3.4 | 4.1 | 5.4 | 6 | 7.3 |
Water Connection ( inch) | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 |
Sound level at 1m (dB(A)) | 55 | 53 | 52 | 52 | 56 | 55 | 55 |
Net Dimension L*W*H(mm) | 810*293*515 | 810*293*515 | 970*360*585 | 1045*370*625 | 1045*370*625 | 1110*416*711 | 1110*416*711 |
Qty per 20ft/40HQ(PCS) | 160/328 | 160/328 | 90/240 | 84/232 | 84/232 | 48/156 | 48/156 |
Remarks:The Specifications are subject to changes without notice. |
CODE | WP17 | WP21 | WP26 | WP31 |
Advised pool size (m3) | 25~55 | 30~60 | 35~70 | 45~90 |
Heating Performance Condition: Air 24ºC, Water 26ºC | ||||
Heating Capacity (KW) | 17.8 | 21.2 | 25.2 | 30.3 |
COP | 6.03 | 6.2 | 6 | 6.04 |
Heating Performance Condition: Air 15ºC, Water 26ºC | ||||
Heating Capacity (KW) | 15.2 | 18.1 | 21.3 | 24 |
COP | 5.17 | 5.4 | 5.13 | 5.05 |
Operating Air Temperature ºC | -5~43 | |||
Power Supply (V/Hz) | 380V/3PH/50HZ | |||
Rated Input Power(KW) | 2.95 | 3.42 | 4.2 | 5.02 |
Rated Input Current(A) | 5.3 | 6.1 | 7.5 | 10.2 |
Max Heating Current (A) | 6.7 | 7.3 | 9.1 | 13 |
Water Flow Rate (m3/h) | 7.3 | 9 | 11.2 | 13.3 |
Water Connection ( inch) | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 |
Sound level at 1m (dB(A)) | 59 | 60 | 60 | 60 |
Net Dimension L*W*H(mm) | 1110*416*711 | 1110*446*958 | 1110*446*1260 | 1110*446*1260 |
Qty per 20ft/40HQ(PCS) | 48/156 | 48/96 | 24/48 | 24/48 |
Remarks:The Specifications are subject to changes without notice. |