Wotech Air Source Heat Pump incorporates a high-efficiency compressor, a completely new high-efficiency heat exchange system, high-precision electronic expansion valves and other accessories. COP has met national level energy efficiency standards and received national energy efficiency certification.
To reduce carbon emissions to the environment and curb global warming, Wotech developed the R290 air-to-water heat pump. With many advantages such as low carbon emissions and high efficiency, the R290 refrigerant is recognized as the refrigerant with the most potential for development in the industry, contributing to the reduction of carbon emissions and helping to achieve the global goal of carbon neutrality.
Wotech heat pumps are equipped with energy-efficient inverter compressors that allow variable heating capacity adjustment. This increases the efficiency of the entire system and reduces the operating costs of the pump. The higher the coefficient, the more heat can be generated using the same amount of electricity.
DC inverter conversion techniques can achieve equilibrium temperatures, saving power and energy. It adopts DC frequency conversion continuously variable adjustment, which has the advantages of strong power, high efficiency, low noise, stable and reliable performance, and long service life.
Using proprietary Heating Curve Logic, users can set up the system to meet their optimum comfort levels based on the changing heat demand,insulation levels, etc Wotech air to water heat pump can adjust the outlet water temperatures based on the ambient temperature,by continually monitoring and adjusting it in opposite direction with the current ambient temperature levels to ensure the optimum comfort in the living spaces
By heating the water in the system to 65°C, the high temperature kills most bacteria (including Legionella).
Users can set up the system according to their ideal comfort levels based on the changing levels of heat demand, insulation, etc., with proprietary Heating Curve Logic. By continually monitoring and adjusting the outlet water temperature in opposite directions with the current ambient temperature levels, the Wotech air to water heat pump will ensure optimal comfort in the living spaces by adjusting the outlet water temperature based on the ambient temperature.
With Floor Preheating, you can avoid potential floor damage and smoothly transition from the preheating to the heating function, avoiding any floor damage.In addition to protecting the installation, the Floor Drying Up function ensures the heat pump operates optimally and effectively by removing any residual moisture from newly installed floor coils.
Wotech Air Source Heat Pump incorporates a high-efficiency compressor, a completely new high-efficiency heat exchange system, high-precision electronic expansion valves and other accessories. COP has met national level energy efficiency standards and received national energy efficiency certification.
To reduce carbon emissions to the environment and curb global warming, Wotech developed the R290 air-to-water heat pump. With many advantages such as low carbon emissions and high efficiency, the R290 refrigerant is recognized as the refrigerant with the most potential for development in the industry, contributing to the reduction of carbon emissions and helping to achieve the global goal of carbon neutrality.
Wotech heat pumps are equipped with energy-efficient inverter compressors that allow variable heating capacity adjustment. This increases the efficiency of the entire system and reduces the operating costs of the pump. The higher the coefficient, the more heat can be generated using the same amount of electricity.
DC inverter conversion techniques can achieve equilibrium temperatures, saving power and energy. It adopts DC frequency conversion continuously variable adjustment, which has the advantages of strong power, high efficiency, low noise, stable and reliable performance, and long service life.
Using proprietary Heating Curve Logic, users can set up the system to meet their optimum comfort levels based on the changing heat demand,insulation levels, etc Wotech air to water heat pump can adjust the outlet water temperatures based on the ambient temperature,by continually monitoring and adjusting it in opposite direction with the current ambient temperature levels to ensure the optimum comfort in the living spaces
By heating the water in the system to 65°C, the high temperature kills most bacteria (including Legionella).
Users can set up the system according to their ideal comfort levels based on the changing levels of heat demand, insulation, etc., with proprietary Heating Curve Logic. By continually monitoring and adjusting the outlet water temperature in opposite directions with the current ambient temperature levels, the Wotech air to water heat pump will ensure optimal comfort in the living spaces by adjusting the outlet water temperature based on the ambient temperature.
With Floor Preheating, you can avoid potential floor damage and smoothly transition from the preheating to the heating function, avoiding any floor damage.In addition to protecting the installation, the Floor Drying Up function ensures the heat pump operates optimally and effectively by removing any residual moisture from newly installed floor coils.
Market model | WW05VM | WW09VM | WW15VM | WW20VT | |||||
Heating | Output Capacity | Kw | 1.89-4.80 | 3.62-9.20 | 5.89-14.96 | 8.03-20.38 | |||
Input Power | Kw | 0.36-1.09 | 0.71-2.19 | 1.21-3.72 | 1.53-4.70 | ||||
COP | - | 4.39-5.62 | 4.19-5.07 | 4.02-4.86 | 4.34-5.25 | ||||
Input Current | A | 1.64-5.01 | 3.27-10.04 | 5.55-17.04 | 2.60-7.99 | ||||
Heating | Output Capacity | Kw | 1.68-4.43 | 3.21-8.45 | 5.56-14.87 | 7.23-19.02 | |||
Input Power | Kw | 0.58-1.81 | 0.99-3.06 | 1.83-5.68 | 2.08-6.44 | ||||
COP | - | 2.45-2.89 | 2.76-3.26 | 2.62-3.09 | 2.95-3.48 | ||||
Input Current | A | 2.67-8.28 | 4.51-14.01 | 8.36-25.98 | 3.54-10.98 | ||||
Heating | Output Capacity | Kw | 2.30-5.76 | 4.49-11.22 | 7.24-18.10 | 9.78-24.46 | |||
Input Power | Kw | 0.46-1.36 | 0.94-2.75 | 1.58-4.63 | 1.98-5.80 | ||||
COP | - | 4.24-4.96 | 4.08-4.77 | 3.91-4.57 | 4.22-4.94 | ||||
Input Current | A | 2.13-6.22 | 4.30-12.59 | 7.24-21.19 | 3.37-9.86 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 1.48-3.53 | 2.95-7.03 | 3.91-9.30 | 5.63-13.41 | |||
Input Power | Kw | 0.50-1.41 | 0.98-2.76 | 1.46-4.10 | 1.89-5.32 | ||||
EER | - | 2.51-2.96 | 2.55-3.01 | 2.27-2.67 | 2.52-2.97 | ||||
Input Current | A | 2.29-6.44 | 4.49-12.62 | 6.69-18.79 | 3.22-9.05 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R290 | |||||||
Max Water Temperature(without backup heater) | ºC | 75 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | dB(A) | 49 | 50 | 53 | 58 | ||||
Net Dimension (L*W*H) | mm | 1085*440*840 | 1085*440*840 | 1150*430*960 | 1150*430*1400 |
Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.
6.Relevant EU Standards and Legislation:EN14511,EN14825
Market model | WW05VM | WW09VM | WW15VM | WW20VT | |||||
Heating | Output Capacity | Kw | 1.89-4.80 | 3.62-9.20 | 5.89-14.96 | 8.03-20.38 | |||
Input Power | Kw | 0.36-1.09 | 0.71-2.19 | 1.21-3.72 | 1.53-4.70 | ||||
COP | - | 4.39-5.62 | 4.19-5.07 | 4.02-4.86 | 4.34-5.25 | ||||
Input Current | A | 1.64-5.01 | 3.27-10.04 | 5.55-17.04 | 2.60-7.99 | ||||
Heating | Output Capacity | Kw | 1.68-4.43 | 3.21-8.45 | 5.56-14.87 | 7.23-19.02 | |||
Input Power | Kw | 0.58-1.81 | 0.99-3.06 | 1.83-5.68 | 2.08-6.44 | ||||
COP | - | 2.45-2.89 | 2.76-3.26 | 2.62-3.09 | 2.95-3.48 | ||||
Input Current | A | 2.67-8.28 | 4.51-14.01 | 8.36-25.98 | 3.54-10.98 | ||||
Heating | Output Capacity | Kw | 2.30-5.76 | 4.49-11.22 | 7.24-18.10 | 9.78-24.46 | |||
Input Power | Kw | 0.46-1.36 | 0.94-2.75 | 1.58-4.63 | 1.98-5.80 | ||||
COP | - | 4.24-4.96 | 4.08-4.77 | 3.91-4.57 | 4.22-4.94 | ||||
Input Current | A | 2.13-6.22 | 4.30-12.59 | 7.24-21.19 | 3.37-9.86 | ||||
Cooling A35ºC W7ºC | Cooling Capacity | Kw | 1.48-3.53 | 2.95-7.03 | 3.91-9.30 | 5.63-13.41 | |||
Input Power | Kw | 0.50-1.41 | 0.98-2.76 | 1.46-4.10 | 1.89-5.32 | ||||
EER | - | 2.51-2.96 | 2.55-3.01 | 2.27-2.67 | 2.52-2.97 | ||||
Input Current | A | 2.29-6.44 | 4.49-12.62 | 6.69-18.79 | 3.22-9.05 | ||||
Power Supply | V/PH/HZ | 220-240V/1/50HZ | 380-415V/3/50HZ | ||||||
ErP level (35ºC) | - | A+++ | A+++ | A+++ | A+++ | ||||
ErP level (35ºC) | - | A++ | A++ | A++ | A++ | ||||
Water Side Heat Exchanger | - | Plate heat exchanger | |||||||
Display controller | - | LCD touch screen | |||||||
Backup heater(Optional) | Kw | 3kw | |||||||
Epansion vessel | - | 3L | 5L | ||||||
Refrigerant Type | - | R290 | |||||||
Max Water Temperature(without backup heater) | ºC | 75 | |||||||
Working Ambeint Temperature | ºC | -25-43 | |||||||
Water connection | inch | G1-1/4 | |||||||
Sound pressure Level @1m | dB(A) | 49 | 50 | 53 | 58 | ||||
Net Dimension (L*W*H) | mm | 1085*440*840 | 1085*440*840 | 1150*430*960 | 1150*430*1400 |
Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.
6.Relevant EU Standards and Legislation:EN14511,EN14825