1.High efficiency and eco-friendly Refrigerant
2High COP(Coefficientofperformance),it can reduce the running cost by 70%-80% compared with other ordinary hot water equipment
3.Can heat and cool the water or keep water temperature constant for pool
4.Dual speed fan for extra energy efficiency and noise reduction
suiable for Koi ponds as well as swimming pools and sauna or SPA
5.Defrosting under low temperature to avoid freezing works down to -10C
6.Titanium heat exchnager-Use patented hig-performance titanium exchanger made from one model by Wotech sub-company.
It has more stable performance,which leads to efficient heat transfer without any dangers of corrosion from chlorine in the water,and createds a longer lifespan.
7.The elegant digital remote control and panel,panted socket-style PCB make maintains easier and operation simple
8.Use the high-efficiency,low sound rotary or scroll compressor,low noise fan.
9.The new generation water flow switch with better performance and longer lifetime.
10.We fuse intelligent,wireless,central control and monitor multiple units with full IT company internet interface that can be applied worldwide
Once the ECO mode is selected, Wotech R32 multifunction heat pump automatically sets the outlet water temperature based on the outdoor ambient air temperature.
Easily control your climate remotely from virtually anywhere using your smartphone or tablet. Download the application for free via the App Store and achieve optimal temperature conditions with great energy savings.
The difference between a fixed output and an inverter heat pump is how they deliver the energy needed from the heat pump to meet the heating requirements of a property.
A fixed-output heat pump works by continuously turning on and off. When turned on, the fixed-output heat pump operates at 100% capacity to meet the heating needs of the property..It will continue to do so until the heat demand is met, and will then cycle between on- and off-heating a large buffer in a balancing act to maintain the requested temperature.
An inverter heat pump, however, uses a variable-speed compressor that modulates its output to increase or decrease its speed to match exactly the building's heat demand as the outdoor air temperature changes.
When demand is low, the heat pump reduces its output, limiting the amount of electricity used and the amount of strain placed on the heat pump components, limiting the start-up period
1.High efficiency and eco-friendly Refrigerant
2High COP(Coefficientofperformance),it can reduce the running cost by 70%-80% compared with other ordinary hot water equipment
3.Can heat and cool the water or keep water temperature constant for pool
4.Dual speed fan for extra energy efficiency and noise reduction
suiable for Koi ponds as well as swimming pools and sauna or SPA
5.Defrosting under low temperature to avoid freezing works down to -10C
6.Titanium heat exchnager-Use patented hig-performance titanium exchanger made from one model by Wotech sub-company.
It has more stable performance,which leads to efficient heat transfer without any dangers of corrosion from chlorine in the water,and createds a longer lifespan.
7.The elegant digital remote control and panel,panted socket-style PCB make maintains easier and operation simple
8.Use the high-efficiency,low sound rotary or scroll compressor,low noise fan.
9.The new generation water flow switch with better performance and longer lifetime.
10.We fuse intelligent,wireless,central control and monitor multiple units with full IT company internet interface that can be applied worldwide
Once the ECO mode is selected, Wotech R32 multifunction heat pump automatically sets the outlet water temperature based on the outdoor ambient air temperature.
Easily control your climate remotely from virtually anywhere using your smartphone or tablet. Download the application for free via the App Store and achieve optimal temperature conditions with great energy savings.
The difference between a fixed output and an inverter heat pump is how they deliver the energy needed from the heat pump to meet the heating requirements of a property.
A fixed-output heat pump works by continuously turning on and off. When turned on, the fixed-output heat pump operates at 100% capacity to meet the heating needs of the property..It will continue to do so until the heat demand is met, and will then cycle between on- and off-heating a large buffer in a balancing act to maintain the requested temperature.
An inverter heat pump, however, uses a variable-speed compressor that modulates its output to increase or decrease its speed to match exactly the building's heat demand as the outdoor air temperature changes.
When demand is low, the heat pump reduces its output, limiting the amount of electricity used and the amount of strain placed on the heat pump components, limiting the start-up period
CODE | WP06EV | WP08EV | WP10EV | WP12EV | WP17EV | WP19EV | WP21EV |
Heating Performance Condition: Air 27ºC, Water 27ºC | |||||||
Max Heating Capacity (KW) | 5.7 | 7.1 | 9 | 11.5 | 16.3 | 18.9 | 20.7 |
COP | 5.7~11.2 | 5.8~12.5 | 5.9~12.5 | 5.7~11.9 | 5.5~11.0 | 5.2~11.2 | 5.3~11.8 |
Heating Performance Condition: Air 15ºC, Water 26ºC | |||||||
Max Heating Capacity (KW) | 4.5 | 5.8 | 7.2 | 8.4 | 12.4 | 14.2 | 15.2 |
COP | 4.5~5.6 | 4.7~6.2 | 4.6~5.7 | 4.6~6.2 | 4.5~5.9 | 4.4~6.6 | 4.3~6.5 |
Operating Air Temperature ºC | -15~43 | ||||||
Power Supply (V/Hz) | 220-240V/1PH/50HZ | ||||||
Rated Input Power(KW) | 1.09~0.13 | 1.22~0.15 | 1.52~0.19 | 2.02~0.17 | 2.96~0.32 | 3.63~0.34 | 3.88~0.44 |
Rated Input Current(A) | 5.3 | 5.84 | 7.27 | 9.66 | 14.16 | 17.36 | 18.56 |
Max Heating Current (A) | 6.9 | 7.5 | 9.45 | 12.55 | 18.4 | 22.56 | 24.1 |
Water Flow Rate (m3/h) | 2-4 | 2-4 | 3-5 | 4-6 | 5-7 | 6-8 | 8-10 |
Water Connection ( inch) | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 |
Sound level at 1m (dB(A)) | 40~51 | 40~51 | 40~51 | 40~51 | 41~52 | 44~54 | 45~55 |
Net Dimension L*W*H(mm) | 965*305*560 | 970*360*585 | 970*360*585 | 970*360*585 | 1045*370*625 | 1100*370*710 | 1100*370*710 |
Qty per 20ft/40HQ(PCS) | 120/240 | 90/240 | 90/240 | 90/240 | 84/240 | 48/150 | 48/150 |
Remarks:The Specifications are subject to changes without notice. |
CODE | WP21EVT | WP26EV | WP31EV |
Heating Performance Condition: Air 27ºC, Water 27ºC | |||
Heating Capacity (KW) | 21.2 | 26.4 | 30.5 |
COP | 5.5~11.3 | 5.4~11.5 | 5.4~11.6 |
Heating Performance Condition: Air 15ºC, Water 26ºC | |||
Heating Capacity (KW) | 16.1 | 20.5 | 23.3 |
COP | 4.4~6.4 | 4.4~6.4 | 4.5~6.5 |
Operating Air Temperature ºC | -5~43 | ||
Power Supply (V/Hz) | 380V/3PH/50HZ | ||
Rated Input Power(KW) | 3.89~0.47 | 4.88~0.57 | 5.64~0.66 |
Rated Input Current(A) | 6.96 | 8.73 | 10.1 |
Max Heating Current (A) | 9.1 | 11.4 | 13.1 |
Water Flow Rate (m3/h) | 8-10 | 10-12 | 12-14 |
Water Connection ( inch) | 1-1/2 | 1-1/2 | 1-1/2 |
Sound level at 1m (dB(A)) | 45~55 | 48~58 | 49~59 |
Net Dimension L*W*H(mm) | 1100*370*710 | 1110*410*960 | 1110*410*960 |
Qty per 20ft/40HQ(PCS) | 48/150 | 20/86 | 20/86 |
Remarks:The Specifications are subject to changes without notice. |
CODE | WP06EV | WP08EV | WP10EV | WP12EV | WP17EV | WP19EV | WP21EV |
Heating Performance Condition: Air 27ºC, Water 27ºC | |||||||
Max Heating Capacity (KW) | 5.7 | 7.1 | 9 | 11.5 | 16.3 | 18.9 | 20.7 |
COP | 5.7~11.2 | 5.8~12.5 | 5.9~12.5 | 5.7~11.9 | 5.5~11.0 | 5.2~11.2 | 5.3~11.8 |
Heating Performance Condition: Air 15ºC, Water 26ºC | |||||||
Max Heating Capacity (KW) | 4.5 | 5.8 | 7.2 | 8.4 | 12.4 | 14.2 | 15.2 |
COP | 4.5~5.6 | 4.7~6.2 | 4.6~5.7 | 4.6~6.2 | 4.5~5.9 | 4.4~6.6 | 4.3~6.5 |
Operating Air Temperature ºC | -15~43 | ||||||
Power Supply (V/Hz) | 220-240V/1PH/50HZ | ||||||
Rated Input Power(KW) | 1.09~0.13 | 1.22~0.15 | 1.52~0.19 | 2.02~0.17 | 2.96~0.32 | 3.63~0.34 | 3.88~0.44 |
Rated Input Current(A) | 5.3 | 5.84 | 7.27 | 9.66 | 14.16 | 17.36 | 18.56 |
Max Heating Current (A) | 6.9 | 7.5 | 9.45 | 12.55 | 18.4 | 22.56 | 24.1 |
Water Flow Rate (m3/h) | 2-4 | 2-4 | 3-5 | 4-6 | 5-7 | 6-8 | 8-10 |
Water Connection ( inch) | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 | 1-1/2 |
Sound level at 1m (dB(A)) | 40~51 | 40~51 | 40~51 | 40~51 | 41~52 | 44~54 | 45~55 |
Net Dimension L*W*H(mm) | 965*305*560 | 970*360*585 | 970*360*585 | 970*360*585 | 1045*370*625 | 1100*370*710 | 1100*370*710 |
Qty per 20ft/40HQ(PCS) | 120/240 | 90/240 | 90/240 | 90/240 | 84/240 | 48/150 | 48/150 |
Remarks:The Specifications are subject to changes without notice. |
CODE | WP21EVT | WP26EV | WP31EV |
Heating Performance Condition: Air 27ºC, Water 27ºC | |||
Heating Capacity (KW) | 21.2 | 26.4 | 30.5 |
COP | 5.5~11.3 | 5.4~11.5 | 5.4~11.6 |
Heating Performance Condition: Air 15ºC, Water 26ºC | |||
Heating Capacity (KW) | 16.1 | 20.5 | 23.3 |
COP | 4.4~6.4 | 4.4~6.4 | 4.5~6.5 |
Operating Air Temperature ºC | -5~43 | ||
Power Supply (V/Hz) | 380V/3PH/50HZ | ||
Rated Input Power(KW) | 3.89~0.47 | 4.88~0.57 | 5.64~0.66 |
Rated Input Current(A) | 6.96 | 8.73 | 10.1 |
Max Heating Current (A) | 9.1 | 11.4 | 13.1 |
Water Flow Rate (m3/h) | 8-10 | 10-12 | 12-14 |
Water Connection ( inch) | 1-1/2 | 1-1/2 | 1-1/2 |
Sound level at 1m (dB(A)) | 45~55 | 48~58 | 49~59 |
Net Dimension L*W*H(mm) | 1100*370*710 | 1110*410*960 | 1110*410*960 |
Qty per 20ft/40HQ(PCS) | 48/150 | 20/86 | 20/86 |
Remarks:The Specifications are subject to changes without notice. |