Availability: | |
---|---|
Air source heat pumps are a highly efficient option for meeting both heating and cooling requirements in buildings. Their effectiveness is largely attributed to the presence of a 4-way valve that facilitates seamless switching between heating and cooling modes. The valve operates by reversing the refrigerant flow, enabling the heat pump to extract heat from the outdoor air and transfer it indoors for heating during the winter season, and extract heat from indoors and transfer it outdoors for cooling during the summer season. By leveraging this technology, air source heat pumps can attain superior efficiency levels compared to conventional heating and cooling systems.
The commercial air to water swimming heat pump is specifically engineered to meet the needs of aquatic facilities, including Municipalities, Hotels, Gymnasiums, Resorts, Schools, and other similar locations.
With air source-generated heat, this system is not only cost-effective and dependable but also environmentally friendly, making it accessible to anyone who desires its benefits.
Compared to conventional electric pool heaters, this system is considerably more efficient as it utilizes external air to maintain the pool's temperature. Additionally, it aids in lowering energy expenditures while also decreasing the facility's carbon footprint.
Air source heat pumps are a highly efficient option for meeting both heating and cooling requirements in buildings. Their effectiveness is largely attributed to the presence of a 4-way valve that facilitates seamless switching between heating and cooling modes. The valve operates by reversing the refrigerant flow, enabling the heat pump to extract heat from the outdoor air and transfer it indoors for heating during the winter season, and extract heat from indoors and transfer it outdoors for cooling during the summer season. By leveraging this technology, air source heat pumps can attain superior efficiency levels compared to conventional heating and cooling systems.
The commercial air to water swimming heat pump is specifically engineered to meet the needs of aquatic facilities, including Municipalities, Hotels, Gymnasiums, Resorts, Schools, and other similar locations.
With air source-generated heat, this system is not only cost-effective and dependable but also environmentally friendly, making it accessible to anyone who desires its benefits.
Compared to conventional electric pool heaters, this system is considerably more efficient as it utilizes external air to maintain the pool's temperature. Additionally, it aids in lowering energy expenditures while also decreasing the facility's carbon footprint.
CODE | WP31 | WP35 | WP45 | WP55 | WP80 | WP90 |
Advised pool size (m3) | 45~90 | 50~100 | 60~140 | 80~170 | 110~250 | 130~300 |
Heating Performance Condition: Air 24ºC, Water 26ºC | ||||||
Heating Capacity (KW) | 29.5 | 34.5 | 41.2 | 50.2 | 76.3 | 88.2 |
COP | 5.8 | 5.7 | 5.93 | 5.95 | 5.9 | 5.8 |
Heating Performance Condition: Air 15ºC, Water 26ºC | ||||||
Heating Capacity (KW) | 23.2 | 26.74 | 34.2 | 42.6 | 59.1 | 69.8 |
COP | 4.77 | 4.69 | 4.86 | 4.96 | 4.92 | 4.85 |
Operating Air Temperature ºC | -5~43 | |||||
Power Supply (V/Hz) | 380V/3PH/50HZ | |||||
Rated Input Power(KW) | 5.09 | 6.05 | 6.95 | 8.44 | 12.93 | 15.21 |
Rated Input Current(A) | 9.10 | 10.83 | 12.43 | 15.09 | 23.13 | 27.2 |
Max Heating Current (A) | 11.8 | 14.1 | 16.2 | 19.6 | 30.1 | 35.4 |
Water Flow Rate (m3/h) | 13.3 | 15 | 19.3 | 23.6 | 34.4 | 38.7 |
Water Connection ( inch) | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 |
Sound level at 1m (dB(A)) | 60 | 60 | 62 | 62 | 64 | 64 |
Net Dimension L*W*H(mm) | 700*660*960 | 1480*730*1070 | 1480*730*1270 | 1480*730*1270 | 2170*765*1300 | 2170*765*1300 |
Qty per 20ft/40HQ(PCS) | 48/96 | 10/44 | 10/22 | 10/22 | 6/14 | 6/14 |
Remarks:The Specifications are subject to changes without notice. |
CODE | WP31 | WP35 | WP45 | WP55 | WP80 | WP90 |
Advised pool size (m3) | 45~90 | 50~100 | 60~140 | 80~170 | 110~250 | 130~300 |
Heating Performance Condition: Air 24ºC, Water 26ºC | ||||||
Heating Capacity (KW) | 29.5 | 34.5 | 41.2 | 50.2 | 76.3 | 88.2 |
COP | 5.8 | 5.7 | 5.93 | 5.95 | 5.9 | 5.8 |
Heating Performance Condition: Air 15ºC, Water 26ºC | ||||||
Heating Capacity (KW) | 23.2 | 26.74 | 34.2 | 42.6 | 59.1 | 69.8 |
COP | 4.77 | 4.69 | 4.86 | 4.96 | 4.92 | 4.85 |
Operating Air Temperature ºC | -5~43 | |||||
Power Supply (V/Hz) | 380V/3PH/50HZ | |||||
Rated Input Power(KW) | 5.09 | 6.05 | 6.95 | 8.44 | 12.93 | 15.21 |
Rated Input Current(A) | 9.10 | 10.83 | 12.43 | 15.09 | 23.13 | 27.2 |
Max Heating Current (A) | 11.8 | 14.1 | 16.2 | 19.6 | 30.1 | 35.4 |
Water Flow Rate (m3/h) | 13.3 | 15 | 19.3 | 23.6 | 34.4 | 38.7 |
Water Connection ( inch) | 1-1/2 | 2 | 2 | 2 | 2-1/2 | 2-1/2 |
Sound level at 1m (dB(A)) | 60 | 60 | 62 | 62 | 64 | 64 |
Net Dimension L*W*H(mm) | 700*660*960 | 1480*730*1070 | 1480*730*1270 | 1480*730*1270 | 2170*765*1300 | 2170*765*1300 |
Qty per 20ft/40HQ(PCS) | 48/96 | 10/44 | 10/22 | 10/22 | 6/14 | 6/14 |
Remarks:The Specifications are subject to changes without notice. |